• Effect of Contrast Injection Protocols with Dose Adjusted to the Estimated Lean Patient Body Weight on Aortic Enhancement at CT Angiography

    Yumi Yanaga, Kazuo Awai, Takeshi Nakaura, Seitaro Oda, Yoshinori Funama, Kyongtae T. Bae, Yasuyuki Yamashita

    OBJECTIVE. The objective of our study was to investigate the effect on aortic en­hancement of iodine doses adjusted for the patient estimated lean body weight (LBW) at CT angiography (CTA).

    SUBJECTS AND METHODS.
    CTA for the whole aorta using a 64-MDCT scanner was performed in 97 patients (mean age, 67.4 years) with confirmed or suspected aortoiliac disease. The patients were divided into two groups: a total body weight (TBW) group (n = 49) and an estimated LBW group in = 48). LBW was estimated from the patient weight (TBW) and height. The TBW and estimated LBW groups received 360 mg I/kg of TBW and 450 mg I/kg of estimated LBW of contrast medium, respectively. The relative dose ratio for the esti­mated LBW group versus the TBW group was based on the fact that the standard percentage of body fat in Japanese adults with an average TBW of 60 kg is 20% (360 = 0.8 x 450). Differ­ences in the degree of aortic enhancement and interpatient variability in aortic enhancement between the estimated LBW and TBW group were evaluated.

    RESULTS.
    Mean aortic enhancement was 308.9 HU for the estimated LBW group and 314.1 HU for the TBW group, indicating no significant difference in the degree of en­hancement (Welchs t test, p = 0.61). The interquartile range was smaller for the LBW group than the TBW group (52.8 vs 79.1 HU, respectively); interpatient variability was lower in the estimated LBW group. The aortic attenuation gradient in the TBW group and estimated LBW group was 20.7 and 25.8 HU, respectively; the difference was not statistically significant.

    CONCLUSION.
    The CTA protocol using an estimated LBW-tailored dose yielded more consistent aortic enhancement with reduced interpatient variability than the CTA protocol us­ing a TBW-based dose.