• Quantitative CT Color Mapping of the Arterial Enhancement Fraction of the Liver to Detect Hepatocellular Carcinoma

    Kyung Won Kim.MD Jeong Min Lee, MD Ernst Klotz, PhD Hee Sun Park, MD Dong Ho Lee, MD Ji Young Kim, MD Soo Jin Kim.MD Se Hyung Kim,MD Jae Young Lee, MD Joon Koo Han.MD Byung Ihn Choi, MD

    Purpose: To investigate the diagnostic value of quantitative determi­nation and three-dimensional color mapping of the arterial enhancement fraction (AEF) of the liver for the detection of hepatocellular carcinoma (HCC).

    Materials and Methods:This retrospective study was approved by the institutional review board; informed consent was waived. Eighty-two patients (mean age, 56.2 years ± 10.7 [standard devia­tion!), 69 men (mean age, 57.1 years ± 10.0) and 13 women (mean age, 51.6 years ± 13.6), were followed-up for HCC or liver cirrhosis by using available multiphasic multidetector computed tomographic (CT) scans. Quanti­tative AEF color maps (the ratio of the attenuation incre­ment during the arterial phase to the attenuation incre­ment during the portal venous phase) of the whole liver were created from routine CT images by using prototypic software. Three radiologists independently analyzed a multiphasic CT image set; 4 weeks later, to avoid any potential recall bias, they independently analyzed a com­bined image set of the quantitative color maps and the multiphasic CT images. The additional diagnostic value of the color mapping was evaluated by means of jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis.

    Results: The mean AEF of HCCs (75.6 ± 13.3) was significantly higher than that of liver parenchyma (23.4 ± 8.2) (P < .001). The average JAFROC figure of merit was 0.861 on the initial multiphasic CT image set. This increased to 0.933 on the second session with the combined image set (P < .05). The mean sensitivity for HCC detection in­creased from 71.7% with the multiphasic CT image set to 88.8% with the combined image set.

    Conclusion: Quantitative color mapping of the AEF can increase the sensitivity and diagnostic performance of multiphasic mul­tidetector CT for detecting HCC.