Acquisition Phase | Phase Included | Scan Delay | Respiration Phase | Anatomical Coverage |
Non Contrast | Yes | N/A | Inspiration | Limited to region of interest |
Full Bladder | Yes | When bladder is full | Inspiration | Limited to region of interest |
Venous Phase | Yes | When bladder is emptied | Inspiration | Limited to region of interest |
Delayed Phase | N/A | N/A | N/A | N/A |
Scan Comments: Non-contrast, full bladder, and post-void images are acquired. Scan ranges are limited to a specific area of interest to avoid unnecessary patient dose. The upper abdomen may be required in some cases. All scans are performed using the ALARA principle. 3D post-processing is performed with this protocol. |
Technical Parameters | Parameters |
kVp | 120 |
Effective mAs | Use dose reduction software |
Quality Reference mAs | 290 |
Time (Rotation) | 0.5 sec |
Average Acquisition Time | 5-7 sec |
Collimation | 128 x 0.6mm |
Pitch Value | 0.6 |
Scan Direction | Craniocaudal |
Comments: Dose reduction software is used to reduce patient dose. The quality reference mAs can be lowered on non-contrast and delayed images (250 mAs). |
Reconstruction Parameters | Soft Tissue | Thin Data | Thin Data | Coronal |
Slice Thickness | 3 mm | 0.75 mm | 0.75 mm | 3 mm |
Reconstruction Spacing | 3 mm | 0.5 mm | 0.5 mm | 3 mm |
Reconstruction Algorithm | I40f (2) | I26f (2) | B20f | I40f (2) |
Window Width and Level | 410/10 | 410/10 | 410/10 | 410/10 |
Reconstruction Comments: |
Reconstruction Parameters | Sagittal | ||
Slice Thickness | 3 mm | ||
Reconstruction Spacing | 3 mm | ||
Reconstruction Algorithm | I40f (2) | ||
Window Width and Level | 410/10 | ||
Reconstruction Comments: |
Contrast Parameters | Parameters |
Contrast Type | N/A |
Contrast Volume | N/A |
Saline Flush | N/A |
Injection Rate | N/A |
Oral Contrast | N/A |
Contrast Volume | N/A |
Comments: A 30 mL nonionic contrast/500 mL saline solution is administered retrograde through a Foley catheter to fill the bladder. |