| Specific Anatomic Region | Facial region | |
| Application | Trauma | |
| Author | Rhea JT et al. | |
| Reference Source | Radiol Clin NA Vol. 37 No. 3 May 1999: 489-513 | |
| Scanner Used | GE Hi-Lite Advantage | |
| Injection Rate | N/A | |
| Contrast Volume and Type | None used | |
| Area Scanned | Coronal- from front of nasal bone to behind sphenoid sinuses. Axial- from below maxillae to above frontal sinuses. | |
| Scan Delay | None | |
| Length of Spiral (time) | Not defined | |
| Slice Thickness | Coronal: 3mm Axial: 3m | |
| Table Speed/Pitch | Coronal: 4.5mm/sec Axial: 4.5mm/sec | |
| Reconstruction Interval | Coronal: 3mm or 1 Axial: 3mm or 1 | |
| 3D Technique Used | Shaded surface (SSD) | |
| Comments: 1.Scanning is done in both coronal and axial plane. 2. Data is reconstructed at 1mm interval when MPR or 3D is done. | ||