| Specific Anatomic Region | Kidney | |
| Application | R/O renal obstruction by a stone | |
| Author | Katz et al. | |
| Reference Source | AJR 1996; 166:1319-1322 | |
| Scanner Used | GE HiSpeed Advantage | |
| Injection Rate | No contrast used | |
| Contrast Volume and Type | N/A | |
| Area Scanned | From midportion T-12 to midportion of symphysis | |
| Scan Delay | None | |
| Length of Spiral (time) | 30-40sec | |
| Slice Thickness | 5mm | |
| Table Speed/Pitch | Pitch of 1.6 | |
| Reconstruction Interval | 3mm | |
| 3D Technique Used | None | |
| Comment: Associated findings including hydronephrosis, hydroureter, perinephric soft tissue stranding or edema, and periureteral edema help make the diagnosis even if a stone is poorly seen. | ||