| Specific Anatomic Region | Bone |
| Application | Suspected metastases (focused exam) |
| Author | Fishman EK |
| Reference Source | Personal Communication |
| Scanner Used | Siemens Plus4 Volume Zoom |
| KV / mAs / Time per Rotation (sec) | 120/130/.5 |
| Detector Collimation (mm) | 2.5 or 1 |
| Slice Thickness (mm) | 3 or 1.25 |
| Data Reconstruction Interval (mm) | 2 or 3 or 1 |
| Table Speed (mm per rotation) / Pitch | 15/6 or 6/6 |
| Oral Contrast | N/A |
| IV Contrast Volume and Type | N/A |
| Injection Rate | N/A |
| Scan Delay (sec) | N/A |
| 3D Technique Used | Volume rendering (as needed) |
Comments: - This is a specific bone study, and uses filter B20 for soft tissue of B60 for bone. Using both filters allows excellent imaging of both bone and the soft tissues.
- In select cases or when 3D is needed 1 mm collimations and 1.25 slice thickness are used
- IV contrast is used if associated soft tissue evaluation is needed
|