| Specific Anatomic Region | Portal Vein | |
| Application | Portal vein patency | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 120/165/.5 | |
| Detector Collimation (mm) | 1 or 2.5 | |
| Slice Thickness (mm) | 1.25 or 3 | |
| Data Reconstruction Interval (mm) | 1 or 2 | |
| Table Speed (mm per rotation) / Pitch | 6/6 or 12.5/5 | |
| Oral Contrast | 750 cc of water | |
| IV Contrast Volume and Type | 120 cc of Omnipaque 350 | |
| Injection Rate | 3 cc/sec | |
| Scan Delay (sec) | 50-60 sec | |
| 3D Technique Used | Volume rendering | |
| Comment: This is a portal phase only study, and is a focused examination. In this study, it is better to be "late" in the acquisition, than "early." If in doubt, wait an extra 10-15 seconds. Occasionally delayed images may be helpful. | ||