| Specific Anatomic Region | Hepatic Vascular Tree | |
| Application | Create a vascular map for preoperative evaluation of the liver. (dual phase study) | |
| Author | Fishman EK | |
| Reference Source | Personal Communication | |
| Scanner Used | Siemens Plus4 Volume Zoom | |
| KV / mAs / Time per Rotation (sec) | 120/125/.5 | |
| Detector Collimation (mm) | 1 | |
| Slice Thickness (mm) | 1.25 | |
| Data Reconstruction Interval (mm) | 1 | |
| Table Speed (mm per rotation) / Pitch | 6/6 | |
| Oral Contrast | 750 cc of water | |
| IV Contrast Volume and Type | 120-150 cc of Omnipaque 350 | |
| Injection Rate | 3 cc/sec | |
| Scan Delay (sec) | 25-30/60 | |
| 3D Technique Used | Volume rendering/MIP | |
| Comment: This protocol is a dual phase study that focuses on creating a detailed vascular map. Volume rendering is best for the arterial and venous mapping, but MIP helps with the hepatic veins on the venous phase. | ||