Siemens Definition 64 Slice MDCT Protocols : Chest : 1PE_STUDY_BOLUS_TRACK (Adult) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Source: JHU Protocol | |||||||||||
| Protocol | Range | Series Description | kV | Quality Ref. mAs | (Eff.) mAs | CAREDose/CAREDose 4D | CAREDoseType | CTDIvol | RotTime | Pitch | |
| 1PE_STUDY_BOLUS_TRACK (Adult) | Topogram | Topogram 0.6 T20s | 120 | 0 | 186 | off | CAREDose | 0 | 0.500 | 1.0000000 | |
| PreMonitoring | 120 | 110 | 60 | off | CAREDose4D | 8.66065 | 0.330 | 0.8000000 | |||
| PreMonitoring 9.6 B20f | |||||||||||
| I.V. Bolus | |||||||||||
| Monitoring | 120 | 110 | 60 | off | CAREDose4D | 259.82 | 0.330 | 0.8000000 | |||
| Monitoring 9.6 B20f | |||||||||||
| PE Study | 120 | 110 | 225 | off | CAREDose4D | 16.209 | 0.330 | 0.80 | |||
| PE Study 0.75 B20f -thins | |||||||||||
| PE Study 3.0 B30f | |||||||||||
| PE Study 3.0 B80f - Lung | |||||||||||
| Coll. | Slice | Recon increment | Images | Kernel | Window | API | Comment1 |
|---|---|---|---|---|---|---|---|
| 0.60 | 0.60 | 1 | T20s | Topogram Body | None | ||
| 0.60 | None | ||||||
| 9.60 | 1 | B20f | Abdomen | ||||
| 0.60 | None | ||||||
| 9.60 | 30 | B20f | Abdomen | ||||
| 0.60 | None | ||||||
| 0.75 | 0.5 | 601 | B20f | PE Window | |||
| 3.00 | 2.0 | 151 | B30f | PE Window | |||
| 3.00 | 3.0 | 101 | B80f | Lung |