| Specific anatomic region | pelvis |
| Application | routine pelvis (R/O abscess, mass, etc.) |
| Author | Elliot K Fishman, MD |
| Reference Source | JHU Protocol |
| Scanner Used | 64 Slice |
| KV/Effective mAs/ Rotation time (sec) | 120 / 276/ 0.5 |
| Detector Collimation (mm) | 0.6 |
| Slice thickness (mm) | 5.0mm |
| Pitch | 0.75 |
| Kernel | B30f medium smooth abdomen |
| Reconstruction interval | 5.0mm |
| Image order (acquisition) | Cr-ca |
| Oral contrast | 1000 cc water or Omnipaque-350 in water (100cc of Omnipaque-350 in one gallon of water) |
| IV contrast volume and type | 120 cc Omnipaque 350 |
| Injection rate | 20-25 cc/sec |
| Scan delay (sec) | 60 sec |
| 3D technique used | VRT as needed |
| Comment: Depending ont he case positive p.o. contrast or rectal contrast (2% Hypaque) may be used. | |