| Specific anatomic region | Kidney |
| Application | R/o Kidney mass |
| Author | Elliot K Fishman, MD |
| Reference Source | JHU Protocol |
| Scanner Used | 64 Slice |
| KV/Effective mAs/ Rotation time (sec) | 120 / 250/ 0.33 |
| Detector Collimation (mm) | 0.6 |
| Slice thickness (mm) | 0.75mm (thin) 3.0mm (thick) |
| Pitch | 0.75 |
| Kernel | B20f smooth abdomen window (thin) B30f medium smooth abdomen (thick) |
| Reconstruction interval | 0.5mm (thin) 3.0mm (thick) |
| Image order (acquisition) | Cr-ca |
| Oral contrast | water (1000 cc) |
| IV contrast volume and type | 120 cc Omnipaque 350 |
| Injection rate | 3.0-3.5 cc/sec |
| Scan delay (sec) | Non: 4 sec Arterial: 30 sec Delay: 5 min |
| 3D technique used | VRT & MIP |
| Comment: Also have protocol using 0.5 sec rotation time. If mass seen on arterial phase then a quick venous phase can be added. | |