| Specific anatomic region | Chest Abd |
| Application | Chest Abd routine (R/O masses, stage lymphoma) |
| Author | Elliot K Fishman, MD |
| Reference Source | JHU Protocol |
| Scanner Used | 64 Slice |
| KV/Effective mAs/ Rotation time (sec) | 120/ 300 / 0.5 |
| Detector Collimation (mm) | 0.6 |
| Slice thickness (mm) | 3-5mm |
| Pitch | 0.75 |
| Kernel | B30f medium smooth abdomen window |
| Reconstruction interval | 3-5mm |
| Image order (acquisition) | Cr-ca |
| Oral contrast | Omnipaque-350 in water (100cc of Omnipaque-350 in one gallon of water) |
| IV contrast volume and type | 100-120cc Omnipaque 350 |
| Injection rate | 2-2.5cc/sec |
| Scan delay (sec) | 50-60 sec |
| 3D technique used | MPR & VRT as needed |
| Comment: We use either Hypaque 3% or water in our routine studies | |